Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
4.
Saudi J Kidney Dis Transpl ; 30(4): 913-918, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31464249

RESUMO

Among patients with chronic kidney disease (CKD), hypertension (HTN) is very common and widely recognized to accelerate the progression of CKD and increase the risk for cardiovascular events. Accumulated data indicate that ambulatory blood pressure monitoring (ABPM) is better in detecting HTN than office blood pressure (BP) measurement. The goal of this study is to describe the ABPM characteristics in a group of CKD and hypertensive patients. A transversal study was conducted over a period of six months, to evaluate the ABPM patterns among a group of hypertensive patients with CKD (Group 1) and compared the data with a control group (Group 2). ABPM was performed with measurement rate every 15 min during daytime and 30 min at night. Nondipping BP patterns were defined as the absence of fall in nocturnal systolic and diastolic BP >10% of daytime values. Masked HTN was defined as controlled office BP (<140/90 mm Hg) with an elevated overall average BP by 24-h ABPM (>125/75 mm Hg), and white-coat HTN was defined as association of elevated BP readings (>140/90 mm Hg) in a clinical setting and normal 24-h average BP levels (<130/80 mm Hg). Fifty patients were included in each group. HTN was much longer in duration among hypertensive patients with CKD and frequently associated with obesity, dyslipidemia, and diabetes (64% vs. 39.60%). Positive proteinuria was present in 82% of CKD patients with HTN. CKD patients with HTN received more antihypertensive drugs than Group 2 patients. HTN was much more uncontrolled among CKD patients (60% vs. 24%), more serious with higher daytime and nighttime SBP, and loss of physiologic dipping during nighttime BP measurement (80%). Out-of-office BP monitoring by ABPM may improve the assessment and the successful management of HTN in patients with CKD. Standardized definitions for the diagnosis of masked and white-coat HTN would facilitate research.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Pressão Sanguínea , Hipertensão/diagnóstico , Insuficiência Renal Crônica/complicações , Adulto , Estudos de Casos e Controles , Progressão da Doença , Feminino , Humanos , Hipertensão/etiologia , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Marrocos , Valor Preditivo dos Testes , Prognóstico , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/fisiopatologia , Medição de Risco , Fatores de Risco , Fatores de Tempo
6.
Saudi J Kidney Dis Transpl ; 25(1): 91-5, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24434388

RESUMO

During hemodialysis and related therapies, removal of waste products from the blood is made possible across a semi-permeable membrane. The microbiological quality of treated water (TW) and dialysate influences a number of dialysis-related complications. This article is a review of the microbiological features of TW and dialysate fluid over a six-year period (February 2007 to December 2012) in the Dialysis Unit, 1 st Medico-Surgical Hospital, Agadir, Morocco. Installation of a water treatment unit has been followed by a protocol to check its quality periodically. Results of microbiological monitoring (microorganisms and endotoxins) were collected over a six-year period. Fifty-four samples of TW and 12 samples of dialysate fluid were analyzed for colony forming units (CFU) and endotoxin during this period. All dialysate samples were negative, while in the TW, 9.2% of the samples yielded >100/mL CFU and 16.7% yielded >0.06 EU/mL of endotoxins. These abnormal results happened especially during the first two first years. More frequent disinfection of the distribution loop was the corrective measure. To obtain high-quality water for hemodialysis, the appropriate system must be continuously monitored in order to get high microbiological quality of TW and dialysate fluid.


Assuntos
Bactérias/isolamento & purificação , Endotoxinas/análise , Soluções para Hemodiálise/análise , Diálise Renal , Microbiologia da Água , Poluentes da Água/análise , Purificação da Água , Abastecimento de Água/análise , Bactérias/crescimento & desenvolvimento , Contagem de Colônia Microbiana , Desinfecção , Contaminação de Equipamentos/prevenção & controle , Desenho de Equipamento , Hospitais , Humanos , Membranas Artificiais , Marrocos , Diálise Renal/efeitos adversos , Diálise Renal/instrumentação , Estudos Retrospectivos , Fatores de Tempo , Purificação da Água/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...